Nominal pack voltage51.2 V
Full charge
58.4 V
Discharge cutoff
40 V
Nominal capacity
280 Ah
Nominal energy
14.336 kWh
Unit weight only
86.72 kg
Equivalent unit resistance
4 mΩ
Unit-limited continuous output
280 A / 14.34 kW
BMS sizing for full unit output
16S · ≥280 A
Electrical topology · 16S1PScroll ↔ · 16S
S1 − +S2 − +S3 − +S4 − +S5 − +S6 − +S7 − +S8 − +S9 − +S10 − +S11 − +S12 − +S13 − +S14 − +S15 − +S16 − + −+

Cell-limited estimates assume matched units and even current sharing. Set charge, BMS, busbar and thermal limits from your actual hardware.

Wire and size a 16S1P EVE LF280K pack

The diagram shows sixteen individual 3.2 V, 280 Ah cells connected in series. Each cell is one series group, so pack voltage adds across the groups and the capacity stays at 280 Ah. The 48 V label refers to the equipment class. Use 51.2 V when calculating nominal energy.

Check charger and inverter voltage limits across the battery operating window. Match the BMS to 16 series groups and verify its continuous and surge ratings against the load, interconnects and cooling. Follow the BMS maker’s sense-harness diagram and connection sequence.

Formulas

  • Nominal pack voltage = 16 × cell nominal voltage
  • Pack capacity = parallel cells per group × cell Ah
  • Nominal kWh = pack volts × pack Ah ÷ 1,000

Worked example

16 × 3.2 V gives 51.2 V. Multiplying by 280 Ah gives 14.336 kWh nominal. At the preset upper cell limit of 3.65 V, the pack reaches 58.4 V. At 85% depth of discharge, the nominal-energy estimate before other losses is about 12.19 kWh.

Engineering references

Frequently asked questions

Why does a 48 V EVE LF280K pack show 51.2 V?

Sixteen 3.2 V LiFePO4 cells give 51.2 V nominal. The 48 V name is a system class. Compare your equipment’s DC input range with the lowest and highest operating voltages of the pack.

How many series channels does a 16S1P pack BMS need?

Use a 16S BMS or a configurable BMS that explicitly supports 16 LiFePO4 series groups. Check the manufacturer’s pinout and sense-harness sequencing.

Does the 280 Ah nameplate determine the required BMS amps?

Estimate continuous and surge current from the actual load and the inverter’s low-voltage operating range. The calculator’s unit-limited current uses the entered C-rate and helps bound the pack’s output.