Wire and size a 16S1P EVE LF280K pack
The diagram shows sixteen individual 3.2 V, 280 Ah cells connected in series. Each cell is one series group, so pack voltage adds across the groups and the capacity stays at 280 Ah. The 48 V label refers to the equipment class. Use 51.2 V when calculating nominal energy.
Check charger and inverter voltage limits across the battery operating window. Match the BMS to 16 series groups and verify its continuous and surge ratings against the load, interconnects and cooling. Follow the BMS maker’s sense-harness diagram and connection sequence.
Formulas
Nominal pack voltage = 16 × cell nominal voltagePack capacity = parallel cells per group × cell AhNominal kWh = pack volts × pack Ah ÷ 1,000
Worked example
16 × 3.2 V gives 51.2 V. Multiplying by 280 Ah gives 14.336 kWh nominal. At the preset upper cell limit of 3.65 V, the pack reaches 58.4 V. At 85% depth of discharge, the nominal-energy estimate before other losses is about 12.19 kWh.