Compare balance times from the same cell capacity gap
This comparison uses a 2 Ah imbalance in a 280 Ah LiFePO4 series group. It treats 2 A of active transfer and 50 mA of passive bleed as effective net correction currents. Actual current and time depend on voltage difference, BMS thresholds, temperature and how often balancing is enabled.
The 2 A value is an editable example for a JK BMS model with that current class. Verify your model and its thresholds. Estimate ΔAh from measured charge or known state-of-charge difference. Voltage gap alone is a weak proxy across the flat LFP voltage plateau.
Formulas
ΔAh = group Ah × state-of-charge gap fractionActive balance time in hours = ΔAh ÷ (effective mA ÷ 1,000)Balance windows = ceil(active hours ÷ window hours)
Worked example
Correcting 2 Ah at 2 A takes 1 active hour. At 50 mA it takes 40 active hours. With an hour of balancing per cycle, the estimates are one and forty cycles, respectively.