Estimate CC/CV charging and balancing separately
During constant-current charging, battery-side amps are approximately fixed. Once the charger reaches the voltage limit, current tapers. Enter the SOC where that transition is expected and estimate average taper current as a fraction of the CC value. Use battery-side coulombic efficiency. A charger’s wall-plug efficiency measures a different quantity.
Passive balancing drains excess charge from higher cells. Active hardware transfers charge, so use the effective net correction current for the gap you measured. The calculated on-time is divided by the active balancing window per cycle. Temperature limits, BMS duty cycling and voltage thresholds can reduce the available window.
LiFePO4 has a flat voltage plateau. A voltage gap in mV is useful context, but the estimated time needs a measured capacity or SOC gap. Derive that gap from a controlled charge/discharge observation near a usable endpoint.
Formulas
Charge time = CC amp-hours ÷ effective CC amps + CV amp-hours ÷ effective average CV ampsBalancing hours = ΔAh ÷ (effective mA ÷ 1,000)Cycles = ceil(balancing on-time ÷ active hours per cycle)
Worked example
Correcting a 2 Ah gap at 60 mA takes about 33.33 hours of active balancing, or 34 cycles with one active hour each. At 2 A effective correction current, the same gap takes one active hour.